• Connector.

    Autodesk

    Vendor

  • Connector.

    Trueview

    Title

  • Connector.

    Version

Post Date: 2017-03-10 02:51:49

Author : badger, Submitted : 05/16/17, Version : 2018 , Category: Business , Installer Type: Windows Installer

This installed OK on x64 Win10. Sequenced in App-V v5.1. All good.
Do NOT launch the app during sequencing…
Remove %appdata% and %localappdata% from the exclusion.

Tested the sequence and had an error on launch.

Files not is sequencer, but created outside virt environment, back to sequencer, launhced app, then edited seq and added these files..

%AppData%\Roaming\Autodesk\DWG TrueView 2018 – English\R16\enu
AcLivePreviewContext.dll
ContextualTabSelectorRules.dll

Then the app works fine. Also, if you want to NOT send data to Autodesk… add these reg keys into the App-V package:

[HKEY_CURRENT_USER\SOFTWARE\Autodesk\MC3]“ADAOptIn”=dword:00000000
“ADARePrompted”=dword:00000001
“OverridedByHKLM”=dword:00000000

Author : Yuri Verhoeks - Fikira BV, Submitted : 03/10/17, Version : 2017 , Category: Business

Silent install Trueview:
setup.exe /q /w /i setup.ini

A number of basic changes to installation are done via Setup.ini

Suppress DWG Association dialog at first start:
HKCU \Software\Autodesk\DWG TrueView\R15\dwgviewr-0001:409\Profiles\<<Unnamed Profile>>\General\DwgAlwaysAssociate: 0x00000000

Suppress Data Collection dialog at first start:
HKCU \Software\Autodesk\MC3\ADARePrompted: 0x00000001

Disable Data Collection:
HKCU\Software\Autodesk\MC3\ADAOptIn: 0x00000000